[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 27, Issue 4 (Winter 2010) ::
J Dent Sch GYEAR__, 27(4): 221-227 Back to browse issues page
Evaluation of the accuracy of three common methods in determining hinge axis points
Morteza Neshandar Dr., Parsa Atashrazm Dr., Ezat'ollah Jalalian Corresponding Author: Dr. * , Ali Barzgar Alamdari Dr., Reza Sha'baan Pour Dr.
Associate Professor , Dr.E.Jalalian@dentaliau.ir
Abstract:   (5964 Views)

Background and Aim: Determining the true hinge axis point in order to transfer the orientation relation to articulator is of great importance in reducing occlusal errors. Because of the high cost and time consuming nature of kinematic method in determining hinge axis point, different arbitrary methods have been introduced which rendered controversial results throughout literature. The aim of this study was to evaluate some arbitrary methods for determining hinge axis point and to introduce a precise arbitrary method which has the least distance from kinematic point.

Materials & Methods: This cross-sectional study was performed sequentially on 40 subjects without any TM- disorders with an age range of 21-37. At first true hinge axis point was determined by DENAR hinge axis locator and marked bilateraly on the skin. Then 3 arbitrary points (Beyron, Gysi, Tetruck & Laundeen) was also determined by a flexible ruler and marked on the skin. The distance between the arbitrary points and kinematic point was measured and the data were charted and subjected to Repeated ANOVA and Paired sample test.

Results: According to the results of the study, Beyron method was significantly more accurate than the other two methods. 88.88% of Beyron points were within 3 mm distance from kinematic point, but the other points didn't show any significant difference with each other.

Conclusion: It is concluded that Beyron method has a high accuracy as an arbitrary method and because of its proximity to the true point, application of this method is recommended.

J Dent Sch 2010 27(4): 8

Keywords: Biomechanics, Tempromandibular joint, Centric relation, Dental occlusion, Dental articulators
Full-Text [PDF 300 kb]   (766 Downloads)    
Type of Study: Original Article | Subject: Special
Received: 2010/03/1
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Neshandar M, Atashrazm P, Jalalian E, Barzgar Alamdari A, Sha'baan Pour R. Evaluation of the accuracy of three common methods in determining hinge axis points. J Dent Sch. 2010; 27 (4) :221-227
URL: http://jds.sbmu.ac.ir/article-1-769-en.html


Volume 27, Issue 4 (Winter 2010) Back to browse issues page
مجله دانشکده دندانپزشکی دانشگاه علوم پزشکی شهید بهشتی Shahid Beheshti University Dental Journal
Persian site map - English site map - Created in 0.06 seconds with 31 queries by YEKTAWEB 3730