Microleakage of Bulk-Fill Composites at Two Different Time Points
چکیده:   (442 مشاهده)

Objectives: Microleakage is the main concern in composite restorations. This study aimed to compare the microleakage of two bulk-fill and one conventional composite at two different time points.

Methods: Class II cavities were prepared in 60 premolar teeth and divided into six groups of 20. Groups 1 and 4 were incrementally filled with Grandio composite. Groups 2 and 5 were filled with X-tra fil bulk-fill composite. Groups 3 and 6 were filled with Tetric-N-Ceram bulk-fill composite in one layer. The samples were thermocycled for 5000 cycles between 25-55°C. In groups 1-3, the samples were incubated for 24 hours and then immersed in 1% methylene blue dye. Groups 4-6 were incubated for three months and then immersed in dye. All samples were mesiodistally sectioned and degree of microleakage was scored under a light microscope. The data were analyzed using Mann Whitney and Kruskal-Wallis tests.

Results: The results showed no significant difference among groups 1-5 and 6 in terms of microleakage (P>0.05) but a significant difference was noted between groups 1 and 4 in this regard (P=0.01). The microleakage in groups 4-6 was higher than that in groups 1-3 (P=0.02). Also, microleakage in gingival margins was greater than that in occlusal margins (P=0.02).

Conclusion: The microleakage of bulk-fill composites is comparable to that of conventional composites both at 24 hours and three months after restoration.

متن کامل [PDF 454 kb]   (197 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: تخصصي
دریافت: ۱۳۹۵/۷/۳۰ | پذیرش: ۱۳۹۵/۹/۲۷ | انتشار: ۱۳۹۶/۴/۱۲
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

کد امنیتی را در کادر بنویسید >



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Kianvash Rad N, Javid B, Panahandeh N, Ghasemi A, Kamali A, Mohammadi G. Microleakage of Bulk-Fill Composites at Two Different Time Points. J Dent Sch. 2016; 34 (4) :225-234
URL: http://jds.sbmu.ac.ir/article-1-1548-fa.html
Microleakage of Bulk-Fill Composites at Two Different Time Points. مجله دانشکده دندانپزشکی دانشگاه علوم پزشکی شهید بهشتی. 1395; 34 (4) :225-234

URL: http://jds.sbmu.ac.ir/article-1-1548-fa.html

دوره 34، شماره 4 - ( 9-1395 ) برگشت به فهرست نسخه ها
مجله دانشکده دندانپزشکی دانشگاه علوم پزشکی شهید بهشتی Shahid Beheshti University Dental Journal
Persian site map - English site map - Created in 0.051 seconds with 805 queries by yektaweb 3506