Comparison of regional microshear bond strength of S.E Bond to primary teeth dentin
Beheshte Malekafzali Corresponding Author: Dr. * , Amir Ghassemi Dr., Shiva Razavi Dr.
Assistant Prof., , beheshtehm@yahoo.com
Abstract:   (13518 Views)

Background & Aim: This study was carried out to compare the microshear bond strength of Clearfil SE Bond between the two different regions of primary tooth: incisal and cervical.

Methods & Materials: In this experimental study which was controlled in vitro trial, 20 extracted primary canines without any caries, fracture and structural anomalies were disinfected and stored in normal saline of a room temperature. Every tooth was hemisectioned buccolingually via ground section. From the two resultant mesially and distally sections, one was chosen for the test, randomly. The composite resin material (Ap-xA2) was placed and packed into the micro bore tygon tubing with the height of 1 mm and internal diameter of 0.7 mm. After application of self – etching primer (according to the manufacturers' instructions) over the incisal and cervical (buccal aspect) dentin, tygon tubes containing composite, were placed over these areas and cured for 40''. Microshear bond strength was determined using the microshear machine and also mode of failure was investigated by stereomicroscope in addition. From incisal and cervical regions of primary canines, two specimens were chosen randomly to investigate the dentinal tubules orientation in these regions by SEM.

Results: SEM observations revealed that the dentinal tubules were oblique, both in incisal and cervical, so there was no difference in dentinal tubules orientation between these two regions. Mean microshear bond strength was 33.88±10.67 MPa for incisal and 28.79±11.72 Mpa for cervical region. Adhesive failure was the most predominant mode of failures being observed in both regions.

Conclusion: There was no statistically significant difference in microshear bond strength of Clearfil SE Bond between the incisal and cervical dentin in primary tooth.

J Dent Sch 2006 24(1): 19

Keywords: Microshear bond strength, Dentin bonding agents, Primary teeth, SEM
Full-Text [PDF 385 kb]   (1603 Downloads)    
Type of Study: Original Article | Subject: Special
Received: 2006/09/6
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Malekafzali B, Ghassemi A, Razavi S. Comparison of regional microshear bond strength of S.E Bond to primary teeth dentin. J Dent Sch. 2006; 24 (1) :128-134
URL: http://jds.sbmu.ac.ir/article-1-82-en.html


Volume 24, Issue 1 (Spring 2006) Back to browse issues page
مجله دانشکده دندانپزشکی دانشگاه علوم پزشکی شهید بهشتی Shahid Beheshti University Dental Journal
Persian site map - English site map - Created in 0.06 seconds with 30 queries by YEKTAWEB 3701