J Dent Sch GYEAR__, 34(2): 100-108 Back to browse issues page
Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Mahkameh Moshfeghi, Mohammad Amintavakoli, Dara Ghaznavi, Aisan Ghaznavi *
Assistant Professor , Aisanghaznavi@yahoo.com
Abstract:   (1081 Views)

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements.

Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted into seven dry sheep mandibles. The length of the pins before the insertion was carefully measured by a digital caliper, (0.01mm accuracy). Imaging of the mandible performed using CBCT New Tom VGi. After image reconstruction by NNT Viewer, linear measurements were made on cross-sectional slices (thicknesses of 0.125, 0.5, 1 and 2mm) by three radiologists. The accuracy of measurements assessed using descriptive indices and compared between different slice thicknesses by repeated measures ANOVA.

Results: Repeated measures ANOVA showed a significant difference between different slice thicknesses (P=0.024). According to the least significant difference (LSD) test, the difference in absolute errors was significant in all thicknesses (P=0.024). Measurements at 0.125 mm thickness were significantly different from others, with a higher error rate (mean absolute error=0.17). Measurements at 0.5mm thickness showed a significant difference with those at 0.125 and 2mm (mean absolute error=0.15). Measurements at 2mm thickness were significantly different from those at 0.125 mm thickness (mean absolute error=0.13).The average error rate was lower in 2mm thickness and the measurements were more accurate.

Conclusion: A statistically significant difference was seam between CBCT measurements and actual sizes in different slice thicknesses. The differences were below 1mm, and clinically acceptable

Keywords: Accuracy, Cone-Beam Computed Tomography, Dental Implants, Dimensional Measurement.
Full-Text [PDF 446 kb]   (304 Downloads)    
Type of Study: Original Article | Subject: Special
Received: 2015/12/30 | Accepted: 2016/05/24
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Moshfeghi M, Amintavakoli M, Ghaznavi D, Ghaznavi A. Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro. J Dent Sch. 2016; 34 (2) :100-108
URL: http://jds.sbmu.ac.ir/article-1-1498-en.html
Volume 34, Number 2 (Spring 2016) Back to browse issues page
مجله دانشکده دندانپزشکی دانشگاه علوم پزشکی شهید بهشتی Shahid Beheshti University Dental Journal
Persian site map - English site map - Created in 0.049 seconds with 792 queries by yektaweb 3463